A C-shaped guard ring is acceptable and is standard practice. It's not really a "ring."
-
You do not need a fully closed 360° loop.
-
The guard ring's job is to intercept leakage paths, not form a Faraday cage.
-
Leave an intentional gap where the signal trace enters the +IN node.
-
Do not route the guard under the signal trace or jump layers just to close the loop — that usually does more harm than good.
-
Drive the guard at the same potential as +IN (voltage follower output is fine).